Omni Calculator logo

PVR Calculator - Pulmonary Vascular Resistance

Created by Dominika Śmiałek, MD, PhD candidate
Reviewed by Dominik Czernia, PhD and Jack Bowater
Based on research by
B G Barratt-Boyes, E H Wood Cardiac output and related measurements and pressure values in the right heart and associated vessels, together with an analysis of the hemo-dynamic response to the inhalation of high oxygen mixtures in healthy subjects; The Journal of laboratory and clinical medicine; Jan 1958See 1 more source
Jeffrey W. Skimming, M.D., Sidney Cassin, Ph.D., Wilmer W. Nichols, Ph.D. Calculating Vascular Resistances; Clinical Cardiology; 1997
Last updated: Sep 07, 2023


Use this PVR calculator to determine the patient's pulmonary vascular resistance. What is PVR? Well, PVR helps to estimate the impact of pulmonary hypertension on heart function and determine the reason for any dysregulation.

Below, you can also find an article providing the normal PVR ranges, the Wood units meaning, and what is PVR's real-life use, such as using Wells score calculator in pulmonary embolism.

What is PVR? Pulmonary vascular resistance definition

Pulmonary vascular resistance (known as PVR in medical abbreviations) determines if there has been a change in the arteries that deliver the blood to the lungs.

A quick reminder - this type of circulation also exists under the name pulmonary circulation, and includes the unoxygenated blood that the right ventricle expels into the pulmonary arteries. Then perfusion/ventilation happens, and oxygenated blood from the lungs comes back into the left atrium via the pulmonary veins, to be sent around the body.

If the pressure in the pulmonary arteries and veins is too high, we have pulmonary hypertension. The right ventricle has to pump more forcefully to overcome that pressure and successfully push the blood into the pulmonary vessels. This may lead to right ventricle dilation - where the ventricle becomes too big, and therefore more power has to be put into pushing the blood. As a result, we face right ventricular dysfunction and failure, strongly related to decreased patient survival.

A similar concept to PVR is peripheral resistance, calculated from the systemic circulation.

Normal PVR ranges

Normal PVR ranges vary depending on the source and the association which defines the cut-off limits. However, it tends to be less than 250 dynes * sec * cm-5.

What may cause low PVR?

  • Drugs, vasodilators, which lower both pulmonary and peripheral resistance;
  • High blood pH, known as alkalemia;
  • Low PaCO2, hypocapnia; and
  • A lot of exercises.

On the other hand, what are the reasons for high PVR, and thus pulmonary hypertension?

  • Drugs, vasoconstrictors;
  • Low PaO2, known under the term hypoxemia;
  • Low blood pH, acidemia;
  • High PaCO2, hypercapnia;
  • Atelectasis - the collapse of a lung due to a lack of oxygen exchange, also determined by AA gradient changes; and
  • Pulmonary embolism (you can rule it out with PERC calculator).

PVR calculator formula

Once you know the PVR medical abbreviation use, how do you use it in practice? To calculate PVR you need three items: left atrial pressure (LAP), mean pulmonary artery pressure (MPAP), calculated similarly to mean arterial pressure for peripheral resistance, and cardiac output (CO):

PVR = 80 * (MPAP - LAP) / CO

If we focus on units:

  • MPAP is in [mmHg];
  • LAP is in [mmHg]; and
  • CO is in [L/min].

Therefore, for PVR it's dynes * sec * cm-5.

The normal values for each variable in the formula are as follows:

Variable

Normal value

Mean Pulmonary Arterial Pressure

10 - 20 mmHg

Left Atrial Pressure

6 - 12 mmHg

Cardiac Output

4 - 8 L/min

PVR calculation in practice

Let's put what we've learned to work with an example. We have a patient with suspected right heart failure. We want to check whether he has a normal pulmonary vascular resistance (again: known as PVR in medical abbreviation) or any pulmonary hypertension.

His results are:

  • Mean Pulmonary Arterial Pressure: 23 mmHg;
  • Left Atrial Pressure - 4 mmHg; and
  • Cardiac Output - 6 L/min.

PVR = 80 * (23 mmHg - 4 mmHg) / 6 L/min

PVR = 253.3 dynes * sec * cm^-5

The patient is above the normal PVR range.

We try our best to make our Omni Calculators as precise and reliable as possible. However, neither we nor our content providers warrant the accuracy of the information on this site. All information on this website is for informational purposes only and is not intended to and should not serve as a substitute for medical consultation, diagnosis or treatment. Please consult your health care provider before making any health care decisions. Omni Calculator and its content providers expressly disclaim responsibility, and shall have no liability, for any damages, loss, injury, or liability whatsoever suffered as a result of your reliance on the information contained in this site. Your use of the site is only your own risk.

Dominika Śmiałek, MD, PhD candidate
Mean Pulmonary Arterial Pressure (MPAP)
mmHg
Left Arterial Pressure (LAP)
mmHg
Cardiac Output (CO)
L/min
Results
Pulmonary Vascular Resistance (PVR)
dynes * sec * cm-5
Check out 37 similar cardiovascular system calculators ❤️
6 minute walk testAnkle-brachial indexAortic valve area… 34 more
People also viewed…

Child weight percentile

This weight percentile calculator helps to assess the development of your child and check whether their weight gain is correct.

Meat footprint

Check out the impact meat has on the environment and your health.

Plastic footprint

Find out how much plastic you use throughout the year with this plastic footprint calculator. Rethink your habits, reduce your plastic waste, and make your life a little greener.

Stroke volume

The stroke volume calculator finds the volume of blood that is pumped by your heart in one beat.
Copyright by Omni Calculator sp. z o.o.
Privacy, Cookies & Terms of Service